13369-1-0203 Page 1
INSTALLATION INSTRUCTIONS
AND
OWNER'S MANUAL
DIRECT VENT
GAS FIREPLACE
MODELS
DVS-30-2 DVS-30RF-2
DVS-36-2 DVS-36IP-2 DVS-36RF-2
DVS-42-2 DVS-42IP-2 DVS-42RF-2
EFFECTIVE DATE
FEBRUARY, 2003
WARNING: If not installed, operated and
maintained in accordance with the manu-
facturer's instructions, this product could
expose you to substances in fuel or from
fuel combustion which can cause death or
serious illness.
WARNING: If the information in this
manual is not followed exactly, a fire
or explosion may result causing prop-
erty damage, personal injury or loss
of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your build-
ing.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas sup-
plier, call the fire department.
Installation and service must be per-
formed by a qualified installer, service
agency or the gas supplier.
This appliance may be installed in an
aftermarket, permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by state or
local codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases, unless a certified kit is
used.
The Tahoe Direct Vent Gas Fireplaces
Seitenansicht 0
1 2 3 4 5 6 ... 51 52

Inhaltsverzeichnis

Seite 1 - GAS FIREPLACE

13369-1-0203 Page 1INSTALLATION INSTRUCTIONSANDOWNER'S MANUALDIRECT VENTGAS FIREPLACEMODELSDVS-30-2 DVS-30RF-2DVS-36-2 DVS-36IP-2 DVS-36RF-2DVS-4

Seite 2 - TABLE OF CONTENTS

Page 10 13369-1-0203Framing and Finishing1. Choose unit location.2. Frame in fireplace with a header across the top. It is importantto allow for finis

Seite 3 - IMPORTANT SAFETY INFORMATION

13369-1-0203 Page 11Attention: When fireplace is installed in optional full cabinetmantel or corner mantel the (4) four nailing flanges shown inFigure

Seite 4 - LP-GAS WARNING ODOR

Page 12 13369-1-0203VERTICAL, 90° ELBOW WITH HORIZONTALTERMINATIONFigure 14HORIZONTAL ONLY, STRAIGHT OUT THE BACKWALL FIRESTOPNOPIPE359mm TO 448mm359m

Seite 5 - INTRODUCTION

13369-1-0203 Page 13CORNER INSTALLATION VERTICAL, 90° ELBOW TOHORIZONTAL OUT THE WALLFigure 17CORNER INSTALLATION HORIZONTAL, 45° ELBOWTO HORIZONTAL O

Seite 6 - SPECIFICATIONS

Page 14 13369-1-0203Figure 22Figure 23Positioning the FireplaceDetermine the exact position of the appliance so the direct venttermination will be cen

Seite 7 - VENT COVER

13369-1-0203 Page 15Cutting the Hole (Figures 22 and 23)After the fireplace has been positioned in its permanent location,the hole through the exterio

Seite 8 - CLEARANCES

Page 16 13369-1-0203Termination clearance for buildings with combustible and noncombustible exteriors.Figure 26Vertical Sidewall InstallationsImportan

Seite 9 - GAS SUPPLY

13369-1-0203 Page 17Figure 27A = *Clearance above grade, veranda, porch, deck or balcony[*12 inches (30cm) minimum]B = clearance to window or door tha

Seite 10 - INSTALLATION

Page 18 13369-1-0203Installing Vent Components (Figure 28)Begin the vent system installation by installing the first component,90° elbow to the starti

Seite 11 - °F mini

13369-1-0203 Page 19DVS-30 FRAMING AND FINISHINGInstalling Support Brackets (Figure 29)A horizontal pipe support MUST BE used for each 3 feet ofhorizo

Seite 12 - INSTALLATION (continued)

Page 2 13369-1-0203Section PageImportant Safety Information ...

Seite 13 - ° ELBOW TO

Page 20 13369-1-0203Figure 31Figure 32Figure 33See "Horizontal Termination (for all Models)" Page 22 and"Vertical Termination (for all

Seite 14

13369-1-0203 Page 21DVS-36 & DVS-42 FRAMING AND FINISHINGInstalling Support Brackets (Figure 34)A horizontal pipe support MUST BE used for each 3

Seite 15 - 13369-1-0203 Page 15

Page 22 13369-1-0203DVS-36 & DVS-42 FRAMING AND FINISHING (continued)Cut a 10-1/2 inch x 10-1/2 inch hole through the ceiling, using thecenter po

Seite 16 - TERMINATION CLEARANCES

13369-1-0203 Page 23Locate and mark the center point of the venting pipe. Using a nailon the underside of the roof and drive this nail through this ce

Seite 17 - VENT CLEARANCES

Page 24 13369-1-0203Before you begin: This unit is supplied with a set of five ceramicfiber logs. Do not handle these logs with your bare hands! Al-wa

Seite 18 - VENT SYSTEM IDENTIFICATION

13369-1-0203 Page 257. Place rear (#1) log onto right, rear pin on rear log support.8. Place middle (#2) log between rear log support and burnerpan.9.

Seite 19 - DVS-30 FRAMING AND FINISHING

Page 26 13369-1-0203The standing pilot (750 millivolt system) is a continuous burningpilot. The pilot remains ON even when the main burner is OFF.750

Seite 20 - Figure 33

13369-1-0203 Page 27PIEZO IGNITORPIEZO IGNITORVALVE CONTROL KNOBVALVE CONTROL KNOBVARIABLE REGULATORVARIABLE REGULATOR("HI"-"LO")

Seite 21 - 13369-1-0203 Page 21

Page 28 13369-1-0203Figure 51STANDING PILOT WIRING DIAGRAMManual Operation1. Turn ON/OFF/REMOTE switch to REMOTE position.2. Turn wall thermostat OFF.

Seite 22 - Page 22 13369-1-0203

13369-1-0203 Page 294. Push in gas control knob slightly and turn clock-wise to "OFF." Do not force.5. Close louver front assembly.8. Turn

Seite 23 - 13369-1-0203 Page 23

13369-1-0203 Page 3DVS-36 OR DVS-42 IS A HEATING APPLIANCE WHEN HEATER BAFFLE IS INSTALLED, SEE PAGE 7Do Not Operate This Appliance Without Glass Fron

Seite 24 - LOG PLACEMENT

Page 30 13369-1-0203With proper installation and maintenance, your new Gas Direct Vent Fireplace should provide years of trouble-free service. If youd

Seite 25 - 13369-1-0203 Page 25

13369-1-0203 Page 31The intermittent pilot (120/24 volt system) is ON when the mainburner is ON. When the main burner is OFF the intermittent pilotis

Seite 26 - Page 26 13369-1-0203

Page 32 13369-1-0203FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: If you do not follow these instructions exactly, a fire or explosion may resultcausin

Seite 27 - 13369-1-0203 Page 27

13369-1-0203 Page 33GENERAL: All furnaces have been fire-tested to check forproper operation. This includes, main burner flame, pilotflame, fan oper

Seite 28 - STANDING PILOT WIRING DIAGRAM

Page 34 13369-1-0203POWER INTERRUPTIONSystem shuts off. Restarts whenpower is restored.PILOT FLAME FAILURESecond main operator closes.Module starts t

Seite 29 - LIGHTING INSTRUCTIONS

13369-1-0203 Page 35Important1. The following service procedures are provided as a gen-eral guide.2. Meter readings between gas control and ignition m

Seite 30 - Page 30 13369-1-0203

Page 36 13369-1-0203Note: Before troubleshooting, familarize yourself with the startup and checkout procedure.Check line voltage power, low

Seite 31 - JUNCTION BOX

13369-1-0203 Page 37RF STANDING PILOT OPERATING INSTRUCTIONSFeatures Benefits• Self powered millivolt receiver/valve • No external power or batteries

Seite 32 - TO TURN OFF GAS TO APPLIANCE

Page 38 13369-1-0203RF WIRING DIAGRAMFigure 54

Seite 33 - 13369-1-0203 Page 33

13369-1-0203 Page 39STANDING PILOT LIGHTING INSTRUCTIONSRF STANDING PILOT LIGHTING INSTRUCTIONS

Seite 34 - Page 34 13369-1-0203

Page 4 13369-1-0203Some people cannot smell well. Some people cannot smell theodor of the chemical put into the gas. You must find out if youcan smell

Seite 35 - 13369-1-0203 Page 35

Page 40 13369-1-0203PLEASE NOTEIt is normal for appliances fabricated of steel to give off someexpansion and/or contraction noised during the start up

Seite 36 - S8600H TROUBLESHOOTING GUIDE

13369-1-0203 Page 411 11785 UPPER CLEARANCE SPACER2 10285 TOP STANDOFF (2 REQ’D)3 11265 VENT COVER PLATE ASSEMBLY4 11264 OUTER WRAPPER TOP5 11263 TOP

Seite 37 - 13369-1-0203 Page 37

Page 42 13369-1-0203DVS-36 PARTS LISTINDEX PART NO. NUMBER DESCRIPTIONINDEX PART NO. NUMBER DESCRIPTION1 11785 UPPER CLEARANCE SPACER2 11450 TOP STA

Seite 38 - RF WIRING DIAGRAM

13369-1-0203 Page 43DVS-42 PARTS LISTINDEX PART NO. NUMBER DESCRIPTIONINDEX PART NO. NUMBER DESCRIPTION1 11785 UPPER CLEARANCE SPACER2 11451 TOP STA

Seite 39 - 13369-1-0203 Page 39

Page 44 13369-1-0203PARTS VIEW

Seite 40 - MAINTENANCE AND SERVICE

13369-1-0203 Page 45The following accessory parts can be obtained from your Empire Comfort Systems, dealer. Should you need additional informationbeyo

Seite 41 - DVS-30 PARTS LIST

Page 46 13369-1-0203Optional FB-BK-2 Blower InstallationandFactory Installed FB-BK-RF Blower1. If applicable, turn OFF electric supply to fireplace.2.

Seite 42 - DVS-36 PARTS LIST

13369-1-0203 Page 47FAN SWITCHFAN SWITCHFAN KITFAN KITSPEED CONTROLSPEED CONTROLJUNCTION BOXJUNCTION BOXWiringThe appliance, when installed, must be e

Seite 43 - DVS-42 PARTS LIST

Page 48 13369-1-0203OPTIONAL SINGLE SPEED BLOWER INSTALLATION INSTRUCTIONS1. If applicable, turn OFF electric supply to fireplace.2. Lower bottom louv

Seite 44 - PARTS VIEW

13369-1-0203 Page 49 INDEX PART DESCRIPTION QUANTITY NUMBER NUMBER SUPPLIED1 11935 BLOWER DIVERTOR 12 R-6458 CORD SET 13 10758 FAN CONTROL BRACKET 1

Seite 45 - ACCESSORY PARTS

13369-1-0203 Page 5INTRODUCTIONInstructions to Installer1. Installer must leave instruction manual with owner afterinstallation.2. Installer must have

Seite 46

Page 50 13369-1-0203OPTIONAL FRESH AIR INTAKE KITDVFB-AK-30, FB-AK-2Optional Fresh Air Intake Kit (Figure 1)Installation of our 6" fresh air inta

Seite 47

13369-1-0203 Page 51Figure 5 Caulk and Install Duct TerminationWALLDUCT TERMINATIONRAIN CAPFigure 4 Example of Installation6. Insert damper rod throu

Seite 48 - FBB1A Blower Installation

Page 52 13369-1-0203SIDE PANELSIDE PANELSIDE PANELSIDE PANELBACK PANELBACK PANELZ BRACKETZ BRACKETINSTALLING OPTIONAL BRICK LINER1. If installed, turn

Seite 49 - PARTS LIST

Page 6 13369-1-0203Model DVS-30(RF) DVS-36(RF) DVS-36IP DVS-42(RF) DVS-42IPInput BTU/HR (KW/H) Maximum 20,000 (5.9) 25,000 (7.3) 25,000 (7.3) 28,000 (

Seite 50 - Page 50 13369-1-0203

13369-1-0203 Page 7Installation of Upper Clearance Spacer for Vertical Vent (Figure 2)Included with every fireplace is the upper clearance spacer. The

Seite 51

Page 8 13369-1-0203MANTELMANTEL4" (102mm)4" (102mm)2 1/2"(64mm)2 1/2"(64mm)10 1/2"10 1/2"(267mm)12"(305mm)TOP EDGE

Seite 52 - -BL-42-2

13369-1-0203 Page 9GAS SUPPLYThe gas pipeline can be brought in through the right or left side ofthe appliance. Consult the current National Fuel Gas